Brand
American Power Conversion(32)
Eaton Bussmann(3)
EA Elektro-Automatik(2)
LITE(26)
Tripp-Lite(40)
Delta Electronics(1)
Block(1)
Epcos(92)
Bourns J.W. Miller(148)
TDK(61)
RS Components(6)
Phoenix(30)
DEHN(5)
Waber(1)
QUAM(1)
Littelfuse(25)
TE Connectivity(8)
Sollatek(1)
Cooper Bussmann(5)
WJ Furse(2)
Wiremold(4)
Superior Electric(2)
Hubbell Wiring Device-Kellems(1)
Roxburgh Electronics(1)
Telegartner(1)
Huber & Suhner(1)
Multiple choices
Encapsulation
(77)
100(1)
Rack(6)
120(2)
88(Max)(1)
83(Max)(1)
Through Hole(3)
-(49)
SMD(6)
Surface Mount(4)
SMD-4(1)
轴向引线(50)
SIP(9)
Axial(2)
Radial, Disc(12)
Metal(2)
Axial Leaded(7)
DFN(1)
径向引线(3)
DIN Rail(20)
1812(1)
SMD-2(31)
9(1)
SON(2)
插件(3)
Radial Leaded(1)
DIN Rail, Screw(1)
Axial Cylinder(47)
SMD-3(9)
Axial Cylinder, Radial Bend(3)
Axial Cylinder, 3 Lead (T-Shape)(11)
Cylinder No Lead(8)
Radial Cylinder, 3 Lead(2)
Axial Cylinder, 3 Lead (Radial Bend)(19)
Cylinder No Lead, 3 Terminal(12)
CylinderNoLead(1)
3终端通孔(6)
(85)
Multiple choices
Packaging
(99)
Bulk(144)
Pallet(1)
Tape & Reel (TR)(111)
Tray(53)
(80)
Bag(3)
Tube(6)
Cut Tape (CT)(2)
Box(1)
Multiple choices
Model/Brand/Package
Category/Description
Inventory
Price
Data
  • Brand: TDK
    Encapsulation:
    Category: Line adjustment
    Description: EL/CCFL Inverter and accessories DC to AC inverter
    2959
    Get WhatsApp Quote
    BOM Quote
  • Brand: Littelfuse
    Encapsulation: SMD-2
    Description: Gas Discharge Tube - GTCS23-XXXM-R01-2 Series TE Connectivity's GTCS23-XXXM-R01-2 series gas discharge tubes have outstanding surge protection characteristics, low capacitance, and two types of transition voltages. These gas discharge tubes are suitable for protecting sensitive equipment, such as in the protection of high data transmission rate telecommunications networks. Namely ADSL and VDSL. ###Features and advantages: 2-pole, 3mm equipment wide voltage range: 75V-600V Shape factor: low capacitance and insertion loss for surface installation # # Application: Telecommunications; RF system protection; Cable TV modem; Hub protection; safety system; data collection
    5223
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: Axial Cylinder
    Description: GTCA28 Series 90V 20kA 20A Through Hole Gas Discharge Tube
    5784
    Get WhatsApp Quote
    BOM Quote
  • Description: TBU ?High speed protector TBU? High-Speed Protectors
    9870
    Get WhatsApp Quote
    BOM Quote
  • Brand: ABB
    Encapsulation:
    Description: OVR Type 1 Surge Protection Device for TNC 230V Network - System Pro M Compact OVR Type 1 Surge Protection Device comes with a status indicator light that can change from green to red at the end of the device's service life. The System Pro M also has a safety reserve system, where when the surge current exceeds the maximum capacitance of the device, the surge protection device will switch to the safety reserve position and the remote indicator light (TS) will switch to the defect. Therefore, users can be warned in advance to have more time to replace the sleeve. Because in the safety reserve position, with the help of a two-stage disconnect system, safety protection can still be ensured. The Pro m compact system is a plug-in device that facilitates maintenance in the event of sleeve failure due to power surges and lightning events. Therefore, replacing the spare sleeve does not require isolating the circuit or disconnecting any related wiring. The auxiliary contact (TS) function is executed by a 3-point 1A voltage free contact, which can remotely check the operating status of surge protection equipment. The applications of System Pro M include green energy systems for solar and wind turbines. ###Surge protection equipment, SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or nearby lightning activity. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.
    7383
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation:
    Description: Transient Voltage Suppressor; 120V; 20A; 2-Wire GND; 25kA (Line-Neutral)
    1258
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation:
    Description: Power Conditioner; 240V; 20A; 2 Wire GND; 25kA (Line-Neutral); lt 0.5ns
    8730
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation:
    Description: Surge Protector Hard Wired 1P 100kA - GR0093985
    6973
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation:
    Description: STV100K10Y - SolaHD TVSS 120/208V 3PH WYE HARDWIRE
    4489
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation:
    Description: "Sola/Hevi-Duty STV100K-24D TVSS Delta Surge Protective Device 240V, 3 Phase, Parallel/Flange Mount, "
    3361
    Get WhatsApp Quote
    BOM Quote
  • Brand: Tripp-Lite
    Encapsulation: Metal
    Description: TRIPP-LITE SS7619-15 Surge Protector, 72inch, 24Outlets, NEMA 5-15R, 15A, 120V, NEMA 5-15P, 4.6m
    2953
    Get WhatsApp Quote
    BOM Quote
  • Brand: WJ Furse
    Encapsulation:
    Description: **Low current power overvoltage protector * * Overvoltage protector is used to protect electronic devices such as CCTV cameras, alarm panels, and telemetry equipment in low current main power supplies. The allowable voltage between all lines is very low (L-E, L-N, N-E), with a sturdy casing and a detachable DIN rail base with M6 grounding terminals, making it easy to install (non boxed version). Flat installation IP66 rated boxed version (/BX components) color coded terminals # # # * * waterproof housing * * ESP protector WBX housing can also be used to provide additional protection in humid and dirty environments. Suitable for situations where protective devices cannot be installed inside existing equipment panels or enclosures. Technical parameters of solid polycarbonate enclosure - | ESP 240-5A | ESP 240-16A | ESP 240-5A/BX | ESP 240-16A/BX Nominal voltage phase neutral _U_o (RMS) | 240V | 240V | 240V | 240V | 240V | 240V Maximum voltage phase neutral _Uc_ (RMS) | 280V | 280V | 280V | 280V | 280V Working voltage (RMS) | 200-280 V | 200-280 V | 200-280 V | 200-280 V | 200-280 V Frequency range | 47-63 Hz | 47-63 Hz | 47-63 Hz | 47-63 Hz | 47-63 Hz Current rating (power supply) | 5A or less | 16A or less | 5A or less | 16A or less maximum spare fuse (see installation instructions) | 5A | 16A | 5A | 16A | 16A leakage current (grounding) | | | Nominal discharge current 8/20 μ s (each mode)/n | 5kA | 5kA | 5kA | 5kA allowable switching voltage max max max n1 | 750V | 750V | 750V | 750V | 750V max discharge current/max (each mode) 1 | 10 KA | 10KA | 10KA | 10KA Temperature Range | -40 to+80 ° C | -40 to+80 ° C | -40 to+80 ° C | -40 to+80 ° C | -40 to+80 ° C Size | 120 x 38 x 54 mm | 120 x 38 x 54 mm | 120 x 56 x 80 mm | 120 x 56 x 80 mm | | | | 1 | For details, please refer to the data sheet | | # # # Recognized UK Rail Network Certification (ESP 240-5A/BX) - PA05/02896. NRS PADS Reference Number: 087/037285 # # # Transient Voltage Suppressor (Module, Industrial Use) Voltage surge (often referred to as peak or tran
    3649
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: 轴向引线
    Description: BOURNS SA2-3600-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 4.32 kV, Axial Lead, 5 kA, 5.4 kV
    8413
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: Axial Cylinder
    Description: SA2Series SA2 High Voltage Gas Discharge Tube
    8795
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: 轴向引线
    Description: BOURNS SA2-5500-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 6.6 kV, Axial Lead, 5 kA, 8 kV
    2013
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: 轴向引线
    Description: BOURNS SA2-6200-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 series, 7.44 kV, Axial Lead, 5 kA, 8 kV
    2973
    Get WhatsApp Quote
    BOM Quote
  • Brand: Tripp-Lite
    Encapsulation:
    Description: TRIPP-LITE RS-1215-RA Multi channel power socket strip, 12 sockets, cable length of 15 feet
    7865
    Get WhatsApp Quote
    BOM Quote
  • Description: TE CONNECTIVITY / RAYCHEM GTCC23-231M-R01-2 Gas Discharge Tube (GDT), Compact Size, R Series, 230V, 2 Terminal SMD, 1kA, 700V
    5686
    Get WhatsApp Quote
    BOM Quote
  • Brand: Littelfuse
    Encapsulation: 轴向引线
    Description: LITTELFUSE AC240L Gas Discharge Tube (GDT), Low Capacity, AC Series, 715 V, Axial Lead, 5 A, 1200 V
    3580
    Get WhatsApp Quote
    BOM Quote
  • Brand: Littelfuse
    Encapsulation: Axial Cylinder
    Description: Gas Discharge Tube (GDT) Products AC and CG3 Series
    3204
    Get WhatsApp Quote
    BOM Quote
  • Brand: DEHN
    Encapsulation:
    Description: DEHNshield The pre wiring of the surge arrester module optimized for applications combines lightning current and surge arrester, and is used for TN-S systems based on spark gap. It is a space saving lightning arrester that combines lightning current and surge arrester, and is used for compact and simple electrical devices that have already been installed. It has reduced technical requirements to protect terminal equipment and provides a readily installable housing with a transparent cover, with a protection level of IP65. Surge protection equipment, SPD (DIN rail) voltage surge, is often referred to as peak or transient overvoltage, which is usually caused by turning off fluorescent lamps, fuse burnout, or nearby lightning activity. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.
    3647
    Get WhatsApp Quote
    BOM Quote
  • Brand: Tripp-Lite
    Encapsulation:
    Description: TRIPP-LITE PM6SN1 Surge Protector, Commercial Grade, Outlet Strip, 6Outlets, NEMA 5-15R, 120VAC
    2172
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: 轴向引线
    Description: Bourns SA Series High Voltage Gas Discharge Tube # # # Transient Voltage Suppressor (Inflatable)
    1125
    Get WhatsApp Quote
    BOM Quote
  • Description: BOURNS SA2-4500-CLT-STD Gas Discharge Tube (GDT), High Voltage, SA2 Series
    2859
    Get WhatsApp Quote
    BOM Quote
  • Brand: Littelfuse
    Encapsulation: Axial Cylinder, 3 Lead (Radial Bend)
    Description: Littelfuse SL1021A Series Gas Discharge Tube Littelfuse SL1021A series GDT plasma arresters offer high levels of performance on fast rising transients such as those induced from lightning disturbances. The Littelfuse SL1021A series also features unltra low capacitance and optimised internal geometry, ensuring low insertion loss at high frequencies. Additionally, the SL1021A series is robust enough to withstand a 10000A pulse without destruction. Applications include broadband equipment, ADSL equipment, XDSL equipment, satellite and CATV equipment as well as general telecom equipment. Ultra low insertion loss Excellent response to fast rising transients ### Transient voltage suppressor (inflation)
    4697
    Get WhatsApp Quote
    BOM Quote
  • Description: STV100K24D4 - SolaHD TVSS 240/480V 3PH DELTA 4 WIRE
    3195
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation:
    Description: STV100K10D4 - SolaHD TVSS 120/240V 3PH DELTA 4 WIRE
    6829
    Get WhatsApp Quote
    BOM Quote
  • Brand: Tripp-Lite
    Encapsulation:
    Description: TRIPP-LITE SUPER7 Surge Protector, White Housing, 7Outlets, NEMA 5-15R, 15A, 120V, NEMA 5-15P, 2m
    9726
    Get WhatsApp Quote
    BOM Quote
  • Encapsulation: Axial Cylinder
    Description: SA2Series SA2 High Voltage Gas Discharge Tube
    9927
    Get WhatsApp Quote
    BOM Quote
  • Brand: ABB
    Encapsulation:
    Description: OVR Type 1 Surge Protection Device for TNC 230V Network - System Pro M Compact OVR Type 1 Surge Protection Device comes with a status indicator light that can change from green to red at the end of the device's service life. The System Pro M also has a safety reserve system, where when the surge current exceeds the maximum capacitance of the device, the surge protection device will switch to the safety reserve position and the remote indicator light (TS) will switch to the defect. Therefore, users can be warned in advance to have more time to replace the sleeve. Because in the safety reserve position, with the help of a two-stage disconnect system, safety protection can still be ensured. The Pro m compact system is a plug-in device that facilitates maintenance in the event of sleeve failure due to power surges and lightning events. Therefore, replacing the spare sleeve does not require isolating the circuit or disconnecting any related wiring. The auxiliary contact (TS) function is executed by a 3-point 1A voltage free contact, which can remotely check the operating status of surge protection equipment. The applications of System Pro M include green energy systems for solar and wind turbines. ###Surge protection equipment, SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or nearby lightning activity. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.
    8512
    Get WhatsApp Quote
    BOM Quote

©Copyright 2013-2025 ICGOODFIND (Shenzhen) Electronics Technology Co., Ltd.

Scroll

Comparison

Unfold

pk

Clear