Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Safety typeDescription: SNO 4062K Safety relay, dual channel LED indication, used for providing automatic restart function of power supply voltage and safety circuit. Contact rated current: 6A in accordance with BS EN 60204 Part 1 1993; EN 954-1; IEC 204-1; VDE 0113 size (mm): H 96.5, W 22.5, L 114 # # # Note stock number 321-9077 has a monostable anti bounce function and sensor for fast touch applications. Equipped with a soft reset function, it allows the device to perform a local reset in the event of a brief interruption. ###Recognize CCC # # # safety relay16721+$3229.884910+$3200.522325+$3185.841050+$3171.1597100+$3156.4784150+$3141.7971250+$3127.1158500+$3112.4345
-
Category: Safety typeDescription: SNA 4063K Safety relays are used for all equipment, including elevators and heaters. They comply with Class 0, EN 60204-1, and can be applied up to Class 4, EN 954-1 to SIL 3. They comply with EN62061, PL e, and EN13849-1. They can be used as emergency stops or safety door monitors. Through self-monitoring on each on-off cycle, they can be manually reset and cross monitored. One or two channels are wired. External equipment monitoring (EDM) LED indicators are used. TUV and cULus are recognized. Safety relays are available9353
-
Category: Safety typeDescription:32151+$951.756410+$918.361450+$914.1870100+$910.0127150+$903.3337250+$897.4896500+$891.64541000+$884.9664
-
Category: Safety typeDescription: Wieland SNO 4083KM Safety Relay SNO 4083KM Safety Relay Function - After applying power voltage to terminal A1/A2 and closing the safety input, the current path (normally open contact) is enabled to close and the signal current path (normally closed contact) can be automatically or opened by pressing the reset button (manual monitoring start). When the safety input is turned on/off, the current path (normally open contact) will immediately open and the signal current path (normally closed contact) will close. The SNO 4083KM safety relay requires fewer connecting cables, whether for operations with or without cross monitoring. The dual channel control of SNO 4083KM is executed by a combination of normally closed/normally closed or normally closed/normally open safety sensors. In the case of dual channel control equipment, the synchronization time between the two channels will be automatically monitored. The safety start function can be used together with manual start, which will automatically reset the input for edge monitoring of rising and falling signals. The monostable trigger function is integrated into the safety relay to prevent equipment interlocking in any situation. The intelligent display system displays the different working modes of safety relays in different applications for users, thus enabling simple diagnosis. Emergency stop monitoring, safety doors, and light barriers application stop category 0, compliant with EN 60204-1 single channel or dual channel control dual channel control, with normally closed/normally closed or normally closed/normally open manual or automatic start cross monitoring synchronous time monitoring, used for dual channel control 3 enable current paths/1 signal current path screw terminal, insertable highest PL e/4 class (EN ISO 13849-1) highest SILCL 3 (EN 62061) # # # recognized CCC # # # safety relay60981+$1961.713610+$1943.879825+$1934.963050+$1926.0461100+$1917.1292150+$1908.2123250+$1899.2954500+$1890.3786
-
Category: Safety typeDescription: SCR-Safety Relays, 2, 054981+$2859.972510+$2833.972825+$2820.972950+$2807.9730100+$2794.9731150+$2781.9733250+$2768.9734500+$2755.9735
-
Category: Safety typeDescription: Altech Safety Relay OA/OW 5669 with Output Contacts 2 and Rated Voltage of 24V. Voltage Range 19.2- 38.4V and Protect...30281+$105.917310+$101.3122100+$100.4833250+$99.8386500+$98.82541000+$98.36492500+$97.72025000+$97.1676
-
Category: Safety typeDescription: Safety Relays OA5670, 110VDC, 2NO/2NC Contacts AgSnO2+0.2umAu, IP4091931+$231.718110+$225.673350+$221.0389100+$219.4270200+$218.2180500+$216.60611000+$215.59862000+$214.5911
-
Category: Safety typeDescription: OA5622S, 12VDC, 3NO/3NC Contacts AgNi10+5umAu, IP4053361+$637.299910+$614.938550+$612.1433100+$609.3482150+$604.8759250+$600.9626500+$597.04941000+$592.5771
-
Category: Safety typeDescription: Safety Relays OA5611, 110V, 2NO/2NC AgNi10+5umAu , IP4081881+$296.945010+$289.198650+$283.2597100+$281.1940200+$279.6447500+$277.57901000+$276.28792000+$274.9968
-
Category: Safety typeDescription: Safety Relays OA5603, 24V, 5NO/3NC AgNi10+.2umAu, IP4097721+$417.336210+$406.449150+$398.1024100+$395.1992200+$393.0218500+$390.11861000+$388.30412000+$386.4896
-
Category: Safety typeDescription: Safety Relay 4 Channel Module, 6P, 10A, 12V,46561+$3117.647510+$3089.305325+$3075.134150+$3060.9630100+$3046.7919150+$3032.6208250+$3018.4496500+$3004.2785
-
Category: Safety typeDescription: 3TK28 26, Configurable Safety Relay, 8 Selectable Functions Simultaneously monitors all of the sensor and actuator functions and ensures that outputs are shut down in a safety-relevant fashion. The safety relay has two terminals for the sensors: The cascading input CAS/OS as sensor input S1. The following components can be connected at the sensor input: sensors with contacts, e.g. EMERGENCY STOP or position switches, electronic sensors, e.g. light grids and light barriers, contact mats, magnetically operated switches, NC/NC or NC/NO. The cascading input can be ANDed with other safety relays or to control the device from a machine control system. Suitable for the following applications: up to category 4 according to EN 954-1, up to SIL 3 according to IEC 61508 Up to eight parameters can be configured therefore reducing the variety of devices in the control cabinet Selectable parameters include: Cross-fault detection, evaluation, connection type, debouncing time, start type sensor input, start type cascading input,start-up test and start-up after power failure. Integrated status display for sensor and actuator states Connection with all conventional sensor types For Cat. 2 according to EN 954-1, only one contactor is required in the shutdown circuit as the shutdown fault in the actuator circuit is automatically signalled Compact design, creates more space in the control cabinet Flexible connectivity Removeable terminals ### Configurable safety relay54211+$2813.621810+$2788.043425+$2775.254250+$2762.4650100+$2749.6759150+$2736.8867250+$2724.0975500+$2711.3083
-
Category: Safety typeDescription: 2Channel Module, 6P, 8A, 24V, 4NO/2NC83951+$1771.080310+$1754.979625+$1746.929250+$1738.8788100+$1730.8285150+$1722.7781250+$1714.7277500+$1706.6774
-
Category: Safety typeDescription: 2Channel Module, 4P, 8A, 12V, 2NO/2NC78131+$1497.134110+$1483.523825+$1476.718650+$1469.9135100+$1463.1083150+$1456.3032250+$1449.4980500+$1442.6929
-
Category: Safety typeDescription: Safety Relay 2 Channel Module, 6P, 8A, 12V,66251+$1771.080310+$1754.979625+$1746.929250+$1738.8788100+$1730.8285150+$1722.7781250+$1714.7277500+$1706.6774
-
Category: Safety typeDescription: 2Channel Module, 4P, 8A, 24V, 2NO/2NC53301+$1497.134110+$1483.523825+$1476.718650+$1469.9135100+$1463.1083150+$1456.3032250+$1449.4980500+$1442.6929
-
Category: Safety typeDescription: 2Channel Module, 4P, 10A, 12V, 3NO/1NC69901+$1282.766110+$1271.104625+$1265.273850+$1259.4431100+$1253.6123150+$1247.7816250+$1241.9508500+$1236.1201
-
Category: Safety typeDescription: Safety Relays RELAY, SSR LATCHING981110+$8.7360100+$8.2992500+$8.00801000+$7.99342000+$7.93525000+$7.86247500+$7.804210000+$7.7750
-
Category: Safety typeDescription: 1Channel Module, 6P, 10A, 24V, 3NO/3NC44891+$985.735210+$951.148050+$946.8246100+$942.5012150+$935.5838250+$929.5310500+$923.47821000+$916.5608
-
Category: Safety typeDescription: OA5611, 12V, 2NO/2NC90491+$230.567010+$224.552250+$219.9408100+$218.3369200+$217.1339500+$215.53001000+$214.52752000+$213.5250
-
Category: Safety typeDescription: ABB JSBT5 The ABB JSBT5 safety relay is a single channel safety relay designed to directly connect safety equipment to the relay in voltage power circuits. It has 3 normally open safety outputs, 1 normally closed output, 1 test input, and complete internal monitoring. The test input is applicable when the contactor or valve has fallen/returned before allowing a new start. The test input can also be used to activate and monitor the start button. JSBT5 has dual sum monitoring internal security function. It can operate safely in the event of power failure, internal component failure, or external interference. ###Features and advantages: Single channel and dual channel test/start input width of 22.5mm LED indicator with 3 normally open/1 normally closed relay outputs. Application: JSBT5 is suitable for monitoring emergency stops and interlocking cabins. ###Note that inventory number 917-6670 has delayed output, 0.5 seconds # # # approved CE, TUV NORD, cSAus. ###Standards 2006/42/EC, 2006/95/EC, 2004/108/EC, EN 62061:2005, EN ISO 13849-1:2008. ###Safety relay12711+$2049.903910+$2031.268425+$2021.950750+$2012.6329100+$2003.3152150+$1993.9974250+$1984.6797500+$1975.3619
-
Category: Safety typeDescription: DOLD & SOEHNE OA 5669.12/983 61 DC 24V Safety relay, OA 5669 series, DPDT, 24 VDC, 8 A, through-hole installation, soldering40991+$60.068010+$57.4563100+$56.9862250+$56.6206500+$56.04601000+$55.78482500+$55.41925000+$55.1058
-
Category: Safety typeDescription: Safety Relays OA5611,110V,2NO/2NC52271+$272.109610+$265.011050+$259.5688100+$257.6759200+$256.2562500+$254.36331000+$253.18022000+$251.9971
-
Category: Safety typeDescription: PILZ 751134 Safety Relay, 3PST-NO, 240V, 6A, PNOZ s4 Series, DIN Rail, Spring Clamp21981+$1748.406010+$1732.511425+$1724.564150+$1716.6168100+$1708.6695150+$1700.7222250+$1692.7749500+$1684.8276
-
Category: Safety typeDescription: PILZ 750135 Safety Relay, 4PST-NO, 240V, 6A, DIN Rail, Screw91641+$3616.631710+$3583.753225+$3567.314050+$3550.8748100+$3534.4355150+$3517.9963250+$3501.5571500+$3485.1178
-
Category: Safety typeDescription: SCHMERSAL AES1135 (24VDC) Safety relay, AES series, 24 VDC, 2 A, DIN rail installation, screws72511+$2220.520510+$2200.334025+$2190.240750+$2180.1474100+$2170.0541150+$2159.9609250+$2149.8676500+$2139.7743
-
Category: Safety typeDescription: PHOENIX CONTACT PSR-SPP- 24DC/RSM4/4X1 Safety relay, PSR series, 4PST normally open, 24 VDC, 5 A, DIN rail installation, cage spring clip9850
-
Category: Safety typeDescription: ABB 2TLJ020024R0000 Key, magnetic, used for JSNY7R switch68061+$173.044010+$168.529850+$165.0689100+$163.8651200+$162.9623500+$161.75851000+$161.00612000+$160.2537
