Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Classification of electronic componentsDescription: ISO 4064 Equipped with pulse transmission equipment and EC75/33 level A/B, the dry dial counter is suitable for remote reading and can be installed in any direction. It comes with a 200cm cable, nut, tail end, and washer wiring. BSPPM outputs 1 liter of power per pulse, rated current 0.2A, rated voltage 30 V, water temperature rating (maximum) 90 ° C, maximum working pressure 16 bar, maximum reading 100M3, minimum reading 0.000M3, including instruction manual dimensions - * * Height without cover (mm) * * | * Length without tail end (mm) * * | * Total length (with tail end) (mm) * * | * Overall diameter (mm) * * * | * Stock number * 66 | 110 | 190 | 72 | 399-5018 70 | 130 | 228 | 72 | 399-5030 130 | 160 | 260 | 100 | 399-5046 # # # Note The impulse emitting device is in the form of a single normally open reed switch which closes momentarily once per litre of water flow. Connections are via a two core cable coloured brown and white connected internally to the water reed switch ### Water Meters - Remote Reading89421+$1097.012910+$1058.521250+$1053.7097100+$1048.8983150+$1041.1999250+$1034.4639500+$1027.72791000+$1020.0295
-
Category: Classification of electronic componentsDescription: Altecnic Mechant When the supply conditions of cold and hot water change and the flow rate is withdrawn, the constant temperature mixing valve can maintain a constant and safe temperature to provide users with domestic hot water supply. Fault safety design can automatically shut off the mixed water flow when the cold and hot water supply to the valve is interrupted. Maximum working pressure: 10 bar - Static minimum working temperature 0.2 bar: Dynamic maximum inlet temperature: 85 ° C Inlet temperature range - Hot water supply: 52-65 ° C \ - Cold water supply: 0.5-20 ° C D08 Working pressure - Low pressure: 0.2-1.0 \ - High pressure: 1.0-5.0 Maximum inlet pressure ratio (hot/cold or cold/hot): 5:1 Accuracy: ± 2 ° C Setting range: 30 to 50 ° C Body DZR - Chrome plating: BS EN 12165 CW602N Spring: Stainless steel Seal: EPDM The design and manufacture of the Merchant series fail safe constant temperature mixing valve comply with the requirements of BS 7942:2000 and National Health Service Model Engineering Specification D08, and are suitable for Healthcare centers, hospitals, sanatoriums, and schools. The standard BS EN 1111: 1999 and BS EN 1287: 1999, as well as the TMV2 series of thermostatically controlled mixing valves for basins, baths, and showers, are all capable of withstanding up to 10:1 hot/cold or cold/hot pressure ratio imbalances. At the same time, all devices include check valves that can prevent cross flow between water supplies, while filters can reduce damage caused by pollution. The joints are secured with compression fittings using 15 or 22 mm pipes.5144
-
Category: Classification of electronic componentsDescription: Altecnic The Altecnic series 311 safety pressure valve is used in household hot water systems to protect the hot water cylinder. It is also used in heating systems to protect boilers and other components. Select the valve for the desired pressure setting. As the pressure increases, when the discharge pressure is reached, the valve opens and releases into the atmosphere, preventing the system pressure from reaching a level that could pose a danger to the boiler, hot water storage cylinder, and any adjacent personnel. Temperature range: 5 to 110 ° C, set pressure range: 2.5 to 8 bar, maximum static pressure: 10 bar. PED category: IV WRAS certified product. Brass body: BS EN 12165 CW617N. Brass cover: BS EN 12165 CW617N. Brass rod: BS EN 12164 CW614N. Diaphragm: EPDM spring: stainless steel control knob: ABS polymer pressure reducing valve and bypass valve76471+$321.057010+$312.681650+$306.2605100+$304.0270200+$302.3519500+$300.11851000+$298.72262000+$297.3267
-
Category: Classification of electronic componentsDescription: Ecocal Thermostatic bimetallic and dual valve fully reversible (maximum differential pressure of 0.3 bar) sliding tailpiece facilitates reverse installation of liquid filling components to ensure accuracy throughout the entire working range. The forward closing position allows for the removal of the radiator without the need to tamper with the system drainage. The valve can be set to a predetermined setting and cannot be adjusted to an economical setting. The valve can be set to only allow adjustment between specific settings and is made of brass. The chrome plated surface also provides matching dual valves. Thermostatic radiator valve32631+$245.533110+$239.127850+$234.2172100+$232.5091200+$231.2281500+$229.52001000+$228.45252000+$227.3850
-
Category: Classification of electronic componentsDescription: ISO 4064 Equipped with pulse transmission equipment and EC75/33 level A/B, the dry dial counter is suitable for remote reading and can be installed in any direction. It comes with a 200cm cable, nut, tail end, and washer wiring. BSPPM outputs 1 liter of power per pulse, rated current 0.2A, rated voltage 30 V, water temperature rating (maximum) 90 ° C, maximum working pressure 16 bar, maximum reading 100M3, minimum reading 0.000M3, including instruction manual dimensions - * * Height without cover (mm) * * | * Length without tail end (mm) * * | * Total length (with tail end) (mm) * * | * Overall diameter (mm) * * * | * Stock number * 66 | 110 | 190 | 72 | 399-5018 70 | 130 | 228 | 72 | 399-5030 130 | 160 | 260 | 100 | 399-5046 # # # Note The impulse emitting device is in the form of a single normally open reed switch which closes momentarily once per litre of water flow. Connections are via a two core cable coloured brown and white connected internally to the water reed switch ### Water Meters - Remote Reading68931+$1128.203310+$1088.617250+$1083.6689100+$1078.7207150+$1070.8035250+$1063.8759500+$1056.94831000+$1049.0311
-
Category: Classification of electronic componentsDescription: Altecnic The flow regulating spherical valve should maintain the insulation of the outlet fittings in the future when the filter element needs to be cleaned. Loose and proportionate filter elements for vacuuming, without continuous blockage and limiting water supply. The automatic flow ink cartridge can provide continuous and constant water flow at the required flow rate and prevent overflow. Flow ink cartridges are easy to replace. Maximum operating temperature: 100 ° C Start differential pressure: 15 kPa Differential pressure range: 15 to 200 kPa Flow rate accuracy:+/-10% Strainers And Isolating Strainers6970