Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Classification of electronic componentsDescription: B (DIN),Used for PT100 and thermocouples, type analog temperature converter, used for PT100 sensors and K-type thermocouple screw connection terminals, clamping range 0.13 → 1.5 mm2 Sensor fault and short circuit detection EMC compliant with EN50081-1 and EN50082-2 * * Universal * * | -------- Loop voltage: | 10 → 36 V DC output: | 4 → 20 mA, current loop, anti reverse polarity output: | 0 → 10 V, short circuit protection working temperature: | -40 ° C →+85 ° C Storage temperature: | -40 ° C →+120 ° C * * LKM 101 is used for K-type thermocouples, 4 → 20 mA * * | Sensor fault | Linear fault: | Fault reference wiring: | ± 0.5 ° C * * LKM 103 Used for PT100, 4 → 20 mA * * | 2/3 wire circuit | Linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>20 mA sensor short circuit: | * * LKM 104 PT100, 0 → 10 V * * | 2-conductor circuit | Power supply voltage: | 18 → 36 V DC Minimum load resistance: | 5 k Ω No load current: | Maximum 40 mA Linear fault: | Sensor fault |>10 V Sensor short circuit: | # # Temperature Transformer34231+$527.738510+$513.971450+$503.4166100+$499.7454200+$496.9919500+$493.32071000+$491.02622000+$488.7317
-
Category: Classification of electronic componentsDescription: LKM 211/213/214 — Transformer, used for PT100 and thermocouple analog temperature converter, used for PT100 sensor and J/K type thermocouple housing: EMG25, polycarbonate sensor fault and short circuit detection EMC compliant with EN50081-1 and EN50082-2 * * Universal * * | ------- Loop voltage: | 10 → 36 V DC output: | 4 → 20 mA, current loop, anti reverse polarity output: | 0 → 10 V, short circuit protection working temperature: | -40 ° C →+85 ° C Storage temperature: | -40 ° C →+120 ° C * * LKM 211, used for thermocouple, 4 → 20 mA * * | Linear fault: | Fault reference wiring: | ± 0.5 ° C Sensor fault |>20 mA * * LKM M 213 is used for PT100, 4 → 20 mA * * | 2, 3 or 4 wire circuits | Linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>20 mA sensor short circuit: | * * LKM 214 is used for PT100, 0 → 10 V * * | 2, 3 or 4-wire circuit | Power supply voltage: | 18 → 36 V DC power consumption: | Approximately 30 mA load resistance: |>5 k Ω linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>10 V sensor short circuit: | # # DIN rail installation1807
-
Category: Classification of electronic componentsDescription: LKM 231 / 232 - Analogue measuring transducer for thermocouple J Analogue measuring transducer for thermocouple type J Standard signal output 4 → 20 mA or 0 → 10 V Input and output galvanically separated Assembly on a 35 mm DIN rail mounting | **LKM 231** | **LKM 232** ---|---|--- Input: | J | J Zero point: | 0 °C → 800 °C | 0 °C → 830 °C Range: | >200 °C | Linearity fault: | | Operating voltage: | 24 Vdc (±10%) | Loop voltage: | 10 → 36 Vdc | - Output: | 4 → 20 mA | 0 → 10 V Sensor break: | >20 mA | >10 V Shortest | = Room temperature | Reaction time: | >1.5 ms | Terminal type: | Screw terminals | Terminal range: | 0.2 → 2.5 mm2 | Housing: | Polycarbonate | Dimensions (H x W x D): | 75 x 25 x 53 mm | Weight: | approx. 60 g | Protection rating: | IP20 | Operating temperature: | -40 °C → +85 °C | ### Approval of CE # # # standard EN50081-1 (EMC emission) EN50081-2 (EMC interference resistance) # # DIN rail installation8435
-
Category: Classification of electronic componentsDescription: LKM110 - transducer for connection head form B, programmable, PT100 Analogue transducer for PT100 For assembly in B head Output signal 4 → 20 mA Programmable with programming kit LKM111 available (option) **LKM110 transducer** | ---|--- Input: | PT100, 2 / 3-wire circuit Measuring current: | max. 0.7 mA Zero point: | -100 °C → +100 °C Range: | 20 °C → 950 °C Linearity fault: | Loop voltage: | 10 → 35 Vdc, resistant to reverse polarity Load: | max. 800 Ω @ 24 V Output: | 4 → 20 mA current loop Sensor break: | >20 mA Short circuit: | Reaction time: | Operating temperature: | -40 °C → +85 °C Terminal type: | Screw terminals Terminal range: | 0.13 → 1.5 mm2 Weight: | 30 g **LKM111 programming kit** | Configuration program: | CD-Rom (for WIN"95 to WIN"XP) Programming cable: | Connection to parallel interface LPT1 ### Recognized CE # # # Standard EN50081-1 (EMC emission), EN50082-2 (EMC interference immunity) ### Temperature Transducer17821+$149.819710+$145.911450+$142.9150100+$141.8727200+$141.0911500+$140.04891000+$139.39752000+$138.7461
-
Category: Classification of electronic componentsDescription: B (DIN),Used for PT100 and thermocouples, type analog temperature converter, used for PT100 sensors and K-type thermocouple screw connection terminals, clamping range 0.13 → 1.5 mm2 Sensor fault and short circuit detection EMC compliant with EN50081-1 and EN50082-2 * * Universal * * | -------- Loop voltage: | 10 → 36 V DC output: | 4 → 20 mA, current loop, anti reverse polarity output: | 0 → 10 V, short circuit protection working temperature: | -40 ° C →+85 ° C Storage temperature: | -40 ° C →+120 ° C * * LKM 101 is used for K-type thermocouples, 4 → 20 mA * * | Sensor fault | Linear fault: | Fault reference wiring: | ± 0.5 ° C * * LKM 103 Used for PT100, 4 → 20 mA * * | 2/3 wire circuit | Linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>20 mA sensor short circuit: | * * LKM 104 PT100, 0 → 10 V * * | 2-conductor circuit | Power supply voltage: | 18 → 36 V DC Minimum load resistance: | 5 k Ω No load current: | Maximum 40 mA Linear fault: | Sensor fault |>10 V Sensor short circuit: | # # Temperature Transformer4869
-
Category: Classification of electronic componentsDescription: LKM 231 / 232 - Analogue measuring transducer for thermocouple J Analogue measuring transducer for thermocouple type J Standard signal output 4 → 20 mA or 0 → 10 V Input and output galvanically separated Assembly on a 35 mm DIN rail mounting | **LKM 231** | **LKM 232** ---|---|--- Input: | J | J Zero point: | 0 °C → 800 °C | 0 °C → 830 °C Range: | >200 °C | Linearity fault: | | Operating voltage: | 24 Vdc (±10%) | Loop voltage: | 10 → 36 Vdc | - Output: | 4 → 20 mA | 0 → 10 V Sensor break: | >20 mA | >10 V Shortest | = Room temperature | Reaction time: | >1.5 ms | Terminal type: | Screw terminals | Terminal range: | 0.2 → 2.5 mm2 | Housing: | Polycarbonate | Dimensions (H x W x D): | 75 x 25 x 53 mm | Weight: | approx. 60 g | Protection rating: | IP20 | Operating temperature: | -40 °C → +85 °C | ### Approval of CE # # # standard EN50081-1 (EMC emission) EN50081-2 (EMC interference resistance) # # DIN rail installation57851+$1402.362510+$1389.613825+$1383.239450+$1376.8650100+$1370.4906150+$1364.1163250+$1357.7419500+$1351.3675
-
Category: Classification of electronic componentsDescription: B (DIN),Used for PT100 and thermocouples, type analog temperature converter, used for PT100 sensors and K-type thermocouple screw connection terminals, clamping range 0.13 → 1.5 mm2 Sensor fault and short circuit detection EMC compliant with EN50081-1 and EN50082-2 * * Universal * * | -------- Loop voltage: | 10 → 36 V DC output: | 4 → 20 mA, current loop, anti reverse polarity output: | 0 → 10 V, short circuit protection working temperature: | -40 ° C →+85 ° C Storage temperature: | -40 ° C →+120 ° C * * LKM 101 is used for K-type thermocouples, 4 → 20 mA * * | Sensor fault | Linear fault: | Fault reference wiring: | ± 0.5 ° C * * LKM 103 Used for PT100, 4 → 20 mA * * | 2/3 wire circuit | Linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>20 mA sensor short circuit: | * * LKM 104 PT100, 0 → 10 V * * | 2-conductor circuit | Power supply voltage: | 18 → 36 V DC Minimum load resistance: | 5 k Ω No load current: | Maximum 40 mA Linear fault: | Sensor fault |>10 V Sensor short circuit: | # # Temperature Transformer82011+$507.597410+$494.355750+$484.2037100+$480.6726200+$478.0243500+$474.49321000+$472.28622000+$470.0793
-
Category: Classification of electronic componentsDescription: LKM 211/213/214 — Transformer, used for PT100 and thermocouple analog temperature converter, for PT100 sensor and J/K type thermocouple housing: EMG25, polycarbonate sensor fault and short circuit detection EMC compliant with EN50081-1 and EN50082-2 DIN rail installation50801+$702.591110+$677.938850+$674.8573100+$671.7757150+$666.8453250+$662.5311500+$658.21691000+$653.2865
-
Category: Classification of electronic componentsDescription: LKM110 - transducer for connection head form B, programmable, PT100 Analogue transducer for PT100 For assembly in B head Output signal 4 → 20 mA Programmable with programming kit LKM111 available (option) **LKM110 transducer** | ---|--- Input: | PT100, 2 / 3-wire circuit Measuring current: | max. 0.7 mA Zero point: | -100 °C → +100 °C Range: | 20 °C → 950 °C Linearity fault: | Loop voltage: | 10 → 35 Vdc, resistant to reverse polarity Load: | max. 800 Ω @ 24 V Output: | 4 → 20 mA current loop Sensor break: | >20 mA Short circuit: | Reaction time: | Operating temperature: | -40 °C → +85 °C Terminal type: | Screw terminals Terminal range: | 0.13 → 1.5 mm2 Weight: | 30 g **LKM111 programming kit** | Configuration program: | CD-Rom (for WIN"95 to WIN"XP) Programming cable: | Connection to parallel interface LPT1 ### 认可 CE ### 标准 EN50081-1 (EMC emission), EN50082-2 (EMC interference immunity) ### Temperature Transducer13681+$539.879010+$525.795250+$514.9976100+$511.2419200+$508.4252500+$504.66951000+$502.32222000+$499.9749
-
Category: Classification of electronic componentsDescription: LKM 211/213/214- Converter, used for PT100 and thermocouple analog temperature converter, used for PT100 sensor and J/K type thermocouple housing: EMG25, polycarbonate sensor fault and short circuit detection EMC compliant with EN50081-1 and EN50082-2 * * Universal * * | ------- Loop voltage: | 10 → 36 V DC output: | 4 → 20 mA, current loop, anti reverse polarity output: | 0 → 10 V, short circuit protection working temperature: | -40 ° C →+85 ° C Storage temperature: | -40 ° C →+120 ° C * * LKM 211, used for thermocouple, 4 → 20 mA * * | Linear fault: | Fault reference wiring: | ± 0.5 ° C Sensor Fault |>20 mA * * LKM 213 for PT100, 4 → 20 mA * * | 2, 3 or 4 wire circuits | Linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>20 mA sensor short circuit: |** LKM 214 is used for PT100, 0 → 10 V * * | 2, 3 or 4 wire circuits | Power supply voltage: | 18 → 36 V DC power consumption: | Approximately 30 mA load resistance: |>5 k Ω linear fault: | Calibration fault: | ± 0.1 ° C sensor fault |>10 V sensor short circuit: | # # DIN rail installation78961+$690.395410+$666.171050+$663.1430100+$660.1149150+$655.2700250+$651.0308500+$646.79151000+$641.9466