Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Classification of electronic componentsDescription: SLP The dual circuit or independent four wire circuit provides protection for ATEX certified multi-stage hybrid protection lines with a maximum rated load current of | 1.50A -------- loop resistance | 2 Ω capacitor (wire wire) | 60pF terminal block | 2.5mm (12 AWG) installation | T-part DIN rail bandwidth (-3dB) | 50MHz # # # surge protection equipment. SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or nearby lightning activity. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.47501+$1238.385510+$1227.127525+$1221.498450+$1215.8694100+$1210.2404150+$1204.6114250+$1198.9823500+$1193.3533
-
Category: Classification of electronic componentsDescription: SLP The dual circuit or independent four wire circuit provides protection for ATEX certified multi-stage hybrid protection lines with a maximum rated load current of | 1.50A -------- loop resistance | 2 Ω capacitor (wire wire) | 60pF terminal block | 2.5mm (12 AWG) installation | T-part DIN rail bandwidth (-3dB) | 50MHz # # # surge protection equipment. SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or nearby lightning activity. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.46241+$1226.732110+$1215.580025+$1210.003950+$1204.4279100+$1198.8518150+$1193.2758250+$1187.6997500+$1182.1237
-
Category: Classification of electronic componentsDescription: 7700 Series safety barrier standard DIN card rail installation detachable, color coded terminal bus power supply to other modules relay and solid-state switch module dual channel variable -6.3mm per channel proximity detector input directly replaced MTL700 series compatible terminal numbers and safety instructions Size: 105 x 90 x 12.6mm Note power supply bus equipment suitable for MTL7706+, 7741 and 7787+barriers MTL 7700 series safety barrier5924
-
Category: Classification of electronic componentsDescription: 5500 The MTL5500 series of IS interface units is the latest generation of MTL isolators. Featuring advanced circuit design and innovative isolation transformer structure. The compact 16mm wide design reduces weight and provides high packing density and low power consumption. They have excellent design and reliable electrochemical isolation advantages based on the successful experience of the MTL5000 series. II (I) GD (Ex ia) IIC、IECEx、ATEX (Baseefa) FM、CSA 3 Port isolation, high packing density, low power consumption, multi-channel input/output module is compatible with the previous MTL5000 series and has been evaluated to comply with functional safety IEC61508. Applications require the Ex number and information to be displayed on the cover (when applicable). MTL 5500 series IS interface unit6859
-
Category: Classification of electronic componentsDescription: 7700 Series safety barrier standard DIN card rail installation detachable, color coded terminal bus power supply to other modules Relay and solid-state switch module Dual channel variable -6.3mm proximity detector input per channel Direct replacement MTL700 series compatible wiring terminal numbers and safety instructions Size: 105 x 90 x 12.6mm * * Manufacturer part number * * | * * Available polarity * * | * Maximum end-to-end resistance (Ω) * * | * * V * * Operating current 10 μ A | * * V * * Maximum | * * Fuse rating (mA) * * | * * Inventory number * *---|---|---|---|---|---|--- MTL7706+ | + | - | - | 35 | 50 | 612-5290 MTL7728+ | + | 333 | 25.9 | 26.5 | 50 | 612-5313 MTL7741 | n/a | n/a | n/a | 30 | 50 | 612-5307 MTL7756 Communication | Communication | 19.0 | (0.7) | 2.7 | 250 | 612-5329 MTL7760 Communication | Communication | 75 | 6.0 | 6.7 | 50 | 612-5341 MTL7877+|+| 333 | 26.6 | 27.2 | 50 | 612-5335 # # # Note that the power bus equipment is suitable for MTL7706+, 7741, and 7787+barriers # # MTL 7700 series safety barriers4076
-
Category: Classification of electronic componentsDescription: MTL7761AC - The strain gauge bridging MTL7700 series barrier protection is located in all equipment that typically experiences explosive gas environments, including air/flammable gas mixtures, dust, and fibers. Single strain gauge bridge for sensing bridge power supply voltage MTL 7700 series safety barrier3002
-
Category: Classification of electronic componentsDescription: 3 The phase power MA3100 series surge protection is designed to cope with high amplitude 10/350 μ s current waveforms described in IEC 61312. IEC Class II surge protection provides remote access to IEC categories | II/C --- Maximum required backup fuses | 125A gL temperature range | -40 ° C to+80 ° C protection type | IP20 flammability rating | V0 maximum impulse current | 45 kA # # # Recognized UL 1449 # # # Surge protection equipment, SPD (DIN rail) voltage surge is often referred to as peak or transient overvoltage, which is usually caused by switch fluorescent lamps, fuse burnout, or nearby lightning activity. The worst voltage surges are usually caused by lightning, with voltages up to 6000V and current surges exceeding 3000A. The maximum value of voltage and current surges caused by lightning strikes depends on the location within the building's wiring system. BS7671: First revised edition in 2011, sections 443 and 534 cover risk assessment and provide guidance on electronic device protection for installation engineers to follow. The BSEN 62305 standard series provides the most comprehensive information on lightning and surge protection.13651+$1092.566910+$1054.231250+$1049.4392100+$1044.6473150+$1036.9801250+$1030.2714500+$1023.56271000+$1015.8955
-
Category: Classification of electronic componentsDescription: 5500 The MTL5500 series of IS interface units is the latest generation of MTL isolators. Featuring advanced circuit design and innovative isolation transformer structure. The compact 16mm wide design reduces weight and provides high packing density and low power consumption. They have excellent design and reliable electrochemical isolation advantages based on the successful experience of the MTL5000 series. II (I) GD (Ex ia) IIC、IECEx、ATEX (Baseefa) FM、CSA 3 Port isolation, high packing density, low power consumption, multi-channel input/output module is compatible with the previous MTL5000 series and has been evaluated to comply with functional safety IEC61508. The Ex number and information need to be displayed on the cover (when applicable) # # # MTL 5500 series IS interface unit3642
-
Category: Classification of electronic componentsDescription: 5500 The MTL5500 series of IS interface units is the latest generation of MTL isolators. Featuring advanced circuit design and innovative isolation transformer structure. The compact 16mm wide design reduces weight and provides high packing density and low power consumption. They have excellent design and reliable electrochemical isolation advantages based on the successful experience of the MTL5000 series. II (I) GD (Ex ia) IIC、IECEx、ATEX (Baseefa) FM、CSA 3 Port isolation, high packing density, low power consumption, multi-channel input/output module is compatible with the previous MTL5000 series and has been evaluated to comply with functional safety IEC61508. The Ex number and information need to be displayed on the cover (when applicable) # # # MTL 5500 series IS interface unit4220
-
Category: Classification of electronic componentsDescription: 5500 The MTL5500 series of IS interface units is the latest generation of MTL isolators. Featuring advanced circuit design and innovative isolation transformer structure. The compact 16mm wide design reduces weight and provides high packing density and low power consumption. They have excellent design and reliable electrochemical isolation advantages based on the successful experience of the MTL5000 series. II (I) GD (Ex ia) IIC、IECEx、ATEX (Baseefa) FM、CSA 3 Port isolation, high packing density, low power consumption, multi-channel input/output module is compatible with the previous MTL5000 series and has been evaluated to comply with functional safety IEC61508. The Ex number and information need to be displayed on the cover (when applicable) # # # MTL 5500 series IS interface unit2092
-
Category: Classification of electronic componentsDescription: 7700 Series safety barrier standard DIN card rail installation detachable, color coded terminal bus power supply to other modules relay and solid-state switch module dual channel variable -6.3mm per channel proximity detector input directly replaced MTL700 series compatible terminal numbers and safety instructions Size: 105 x 90 x 12.6mm Note power supply bus equipment suitable for MTL7706+, 7741 and 7787+barriers MTL 7700 series safety barrier9433
-
Category: Classification of electronic componentsDescription: 5500 The MTL5500 series of IS interface units is the latest generation of MTL isolators. Featuring advanced circuit design and innovative isolation transformer structure. The compact 16mm wide design reduces weight and provides high packing density and low power consumption. They have excellent design and reliable electrochemical isolation advantages based on the successful experience of the MTL5000 series. II (I) GD (Ex ia) IIC、IECEx、ATEX (Baseefa) FM、CSA 3 Port isolation, high packing density, low power consumption, multi-channel input/output module is compatible with the previous MTL5000 series and has been evaluated to comply with functional safety IEC61508. Applications require the Ex number and information to be displayed on the cover (when applicable). MTL 5500 series IS interface unit8088
-
Category: Classification of electronic componentsDescription: 5000 The series IS interface unit has a direct DIN card rail installation channel with low cost and high packaging density. It uses plug-in connectors, simplifying installation and maintenance. The size is 110 x 104 x 16.2mm. PCS45 configuration software is provided, and the standard intrinsic safety certificate can be downloaded for free from the MTL website - www.mtl-inst.com. It complies with ATEX, CSA, UL, and IEC Ex standards. The MTL 5000 series IS interface unit6982
-
Category: Classification of electronic componentsDescription: MTL5561 - The fire and smoke detector interface MTL5561 is a loop powered 2-channel interface designed for use with traditional fire and smoke detectors located in hazardous areas. When running, triggering the detector will cause a corresponding change in the safe zone current. Dual channel reverse input polarity protection without fault grounding fault protection # # # MTL 5500 series IS interface unit4845
