Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE IK 3070.12/00B AC 230V 50/60Hz General Purpose Relay, IK 3070 Series, Interface, DPDT, 230VAC, 3A3506
-
Category: Classification of electronic componentsDescription: IK 8701 - coupler relay High thermal current Ith = 16A Contact assignment 1 NO, 1 or 2 CO Switch for manual operation of the contact Switch position indication 17.5mm overall width **Input** | ---|--- Nom. voltage: | AC 230V 50Hz or dc 24V Voltage ranges: | 0.9 → 1.1 UN Nominal consumption: | AC 1.8VA / dc 1.5W **Output** | Contact assignment: | 1 NO, 1 or 2 changeover contacts Response time/release time: | Thermal current: | 16A Elect. service life: | 16A, 12 x 104 switching cycles/h (AC 230V, ohm resistive load) Acceptable switching frequency: | 1000 switching cycles/h **General data** | Temperature range: | -20℃ to +45℃ Device dimensions: | 17.5 x 89 x 58mm (W x H x D) ### End Relay Couplers4092
-
Category: Classification of electronic componentsDescription: Emergency stop module, BD5987.02 / 001 Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching) Output: 2 N/Os for AC 250 V 1 or 2-channel configuration Line termination detection on the ON button Optional: cross-fault detection in the emergency stop control circuit Optional: automatic on-function when operational voltage is met or system is activated with the ON button LED displays for channel 1 and channel 2 and operational mode Control loop for monitoring external contactors Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113 **Input** | ---|--- Nom. voltage: | AC 230 V or DC 24 V Control voltage on S33: | 24 Vdc Min. Voltage on S12, S21: | DC 21 V (activated device) **Output** | Contact assignment: | 2 N/O Response time with ON button: | max. Downtime in case of interruption: | ..in secondary circuit (S12-S22): | 50 ms ±25% ..in network: | 120 ms ±50% Switching capability according to AC 15: | 5 A / AC 230 V **General data** | Temperature range: | -15 °C → +55 °C Terminal positioning: | Compliant with DIN 46199-4 Device dimensions (W x H x D): | 45 x 74 x 121 mm ### Recognized BG, SUVA, SA (Sweden), UL, CSA # # # Standards EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Safety Relays9684
-
Category: Classification of electronic componentsDescription: Soft starter for AC current drives, IL9017 Robust electronic control unit specially designed for the smooth start-up of single-phase asynchronous machines (AC current motors with auxiliary capacitor) After starting, the power electronics are bridged via an internal relay contact to minimise losses in the device Increases the service life of single-phase asynchronous motors and mechanical drive components For 1.5 kW motor ratings Start-up time and LED displays can be adjusted separately 35 mm overall width Motor nominal voltage: | AC 230 V - 20% + 10% ---|--- Nom. current: | 10 A Motor nominal output: | 1.5 kW Start-up voltage adjustment range: | 20 to 70% Start-up time adjustment range: | 0.1 to 10 s Repeat availability time | 200 ms Switching frequency: | 10 1/h Super-fast-acting semiconductor fuse: | 20 A Temperature range: | 0 → +55 °C Protection type (terminals/housing) | IP 20 / IP 40 Device dimensions (W x H x D) | 35 x 90 x 61 mm Warning* The IL9017 must not be operated with a capacitive load (e.g. reactive power compensation) at the output. In the decoupled state (without load), the starting behaviour is not particularly smooth.2307
-
Category: Classification of electronic componentsDescription: IK8810 - stair light time switch Stair light time switch for DIN rails Switch for continuous light on device Overall width 17.5 mm 16 A contact LED status display ### note Device and button must be connected to the same phase. Contact output is not volt-free ### Approval of CE # # # Standard EN60669 # # # Stairs4685
-
Category: Classification of electronic componentsDescription: Insulation monitor for direct current networks, AI898 Fixed response time 6kΩ LED display for operational readiness and earth fault 1 changeover Overall width 45mm The AI898 insulation monitor displays the insulation resistance of unearthed direct current networks to earth. It does not detect symmetrical earth faults. In practice, these faults are generally insignificant. The AI898 works on the quiescent current principle, for example when the auxiliary voltage is applied to terminals A1 → A2 the output relay is activated and the "ON" LED indicates that the insulation resistance RAN is not less than the minimum value. If insulation resistance falls below the response value, the output relay drops, the "ON" LED goes out and the second LED for "Earth fault" lights up. A bridge between terminals LT1 and LT2 (inserted as standard) allows the AI898 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. A test key (PT) tests the functional efficiency of the device (as per VDE 0435). **Input** | ---|--- Internal resistance/measuring current: | Auxiliary voltage UH: | 5kΩ / Auxiliary voltage range: | 230Vac, 45 → 400V **Output** | 0.8 → 1.1uH Thermal current: | Switching capacity: | | | | 8A | 3A (AC 11, 230V) | 2A (DC 11, 24V) ### Insulation monitor2175
-
Category: Classification of electronic componentsDescription: IK 3070 - coupler relay Coupler relay for small and large loads, as link between control and power levels For electrical isolation in accordance with EN 61810 Secure isolation in accordance with VDE 0106 part 101 2 NO contacts or 2 changeover contacts **Input** | ---|--- Nominal voltage UN: | 24VDC or 230Vac Voltage range: | DC 0.9 to 1.2 UN / AC 0.8 to 1.1 UN Power consumption: | DC approx. 0.5W(1/2W) / AC approx. 0.9W **Output** | Response time / release time: | Making capacity: | min 0.3A / max. 8A or, 2 x 5A simultaneously Thermal current Ith: | max. 8A Switching capability according to AC 15: | 3A @ 230Vac EN 60 947-5-1 Electrical service life: | >2.5 x 105 switching cycles (at AC 15 and 3A/230V ac) Acceptable switching frequency: | max. 10 switching cycles / s Mechanical lifespan: | >50 x 106 **General data** | Rated operating current type: | Continuous Temperature range: | -20℃ → +55℃ Protection type (housing / terminals): | IP 40 / IP 20 , EN 60 529 Line terminal: | 2 x 2.5mm 2 solid or, 2 x 1.5mm 2-strand with sleeve, DIN 46 228-1/-2/-3 Width x height x depth: | 17.5 x 90 x 58mm ### End Relay Couplers1190
-
Category: Classification of electronic componentsDescription: IK8839.11 - Current relay Fixed switching point High overload capacity Compact design Switching capability according to AC 11: 2A @ 230V ac Thermal current: 8A Overload capacity, permanent: approx. 20A Overload capacity, for 2 s: approx. 150A The IK8839 is a single phase relay for monitoring the operating current of electrical consumers and works on the quiescent current principle. Its i-k current path is galvanically separated from the remaining part of the device by a current transformer. An auxiliary voltage must be applied to terminals A1 → A2 (in accordance with IEC 255, VDE 0345). ### Dold Monitoring Relay9498
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE IK 3070.02/002 DC 24V General Purpose Relay, IK 3070 Series, Interface, DPST-NO, 24VDC, 3A8888
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE PH 9260.91 AC 24 - 240V AC 50A Solid state relay, 50 A, panel mounted, screws, 24 VAC, 240 VAC95161+$260.323210+$253.532250+$248.3257100+$246.5148200+$245.1565500+$243.34561000+$242.21382000+$241.0819
-
Category: Classification of electronic componentsDescription: Time Delay Relay, Dpdt, 300H, 230VAC76351+$781.384510+$753.967550+$750.5404100+$747.1133150+$741.6299250+$736.8319500+$732.03391000+$726.5505
-
Category: Classification of electronic componentsDescription: BA7924.21 delay module Adjustable off delay No auxiliary voltage Output: 1 NC, 1 force guided NO LED to display switch position Delayed switch-off in safety-oriented circuits (EU Directive for machines 89/392/EEC, IEC 255, DIN VDE 0435) Time range: | 1 → 10 s ---|--- Repeat accuracy: | ±15 % Minimum connection time: | 50 % of the end scale value **Input** | Nom. voltage: | 24 Vdc Voltage range: | 0.9 → 1.1 UN **Output** | Contact assignment: | 1 NC, 1 NO Contact type | Relay, force guided Nominal output voltage: | AC 10 → 250 V, DC 10 → 110 V Thermal current: | max. 8 A Switching capability according to AC 15: | 5 A / AC 230 V Permitted Switching frequency: | max. 2000 cycles/h but note minimum connection time **General data** | Temperature range: | -20 °C → +60 °C Device dimensions (W x H x D): | 45 x 74 x 133 mm ### Standard EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Safety Relays7683
-
Category: Classification of electronic componentsDescription: Emergency stop module, BD5987.02 / 001 Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching) Output: 2 N/Os for AC 250 V 1 or 2-channel configuration Line termination detection on the ON button Optional: cross-fault detection in the emergency stop control circuit Optional: automatic on-function when operational voltage is met or system is activated with the ON button LED displays for channel 1 and channel 2 and operational mode Control loop for monitoring external contactors Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113 **Input** | ---|--- Nom. voltage: | AC 230 V or DC 24 V Control voltage on S33: | 24 Vdc Min. Voltage on S12, S21: | DC 21 V (activated device) **Output** | Contact assignment: | 2 N/O Response time with ON button: | max. Downtime in case of interruption: | ..in secondary circuit (S12-S22): | 50 ms ±25% ..in network: | 120 ms ±50% Switching capability according to AC 15: | 5 A / AC 230 V **General data** | Temperature range: | -15 °C → +55 °C Terminal positioning: | Compliant with DIN 46199-4 Device dimensions (W x H x D): | 45 x 74 x 121 mm ### Recognized BG, SUVA, SA (Sweden), UL, CSA # # # Standards EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Safety Relays6283
-
Category: Classification of electronic componentsDescription: Emergency Stop Module, BD5935.48 Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching) Ultra compact unit (width 45 mm) Output: 3 N/Os, 1 N/C 1 or 2-channel configuration Line termination detection on the ON button Programmable: cross-fault detection in emergency stop-control loop Programmable: automatically comes on when operational voltage is applied or activation must happen with the ON button LED indicators for channels 1 and 2 Option to monitor external protection Removable terminals Protection of humans and machines in accordance with: EC Directive for Machines 89/392/EEC, IEC 204 T 1, EN 60204 T 1, DIN VDE 0113 **Input:** | ---|--- Nom. voltage: | AC 230 V or DC 24 V Control voltage on S11: | 24 Vdc Min. voltage on S12, S21: | DC 21 V (activated device) **Output:** | Contact assignment: | 3 N/O, 1 N/C Response time with ON button: | 50 ms -25% +50% Response time, automatic: | 1 s -25% +50% On: | Downtime in case of interruption: | ...in secondary circuit (S12-S22): | 25 ms -25% +50% ...in network: | 50 ms -25% +50% Switching capability according to AC 15: | 5A / AC 250 V (N/O) | 2 A / AC 250 V (NC) **General data:** | Temperature range: | -15 °C → +55 °C Terminal positioning: | Compliant with DIN 46199-4 Device dimensions (W x H x D): | 45 x 74 x 121 mm ### Recognized BG # # # Standard EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Safety Relays8809
-
Category: Classification of electronic componentsDescription: Emergency Stop Module, BD5935.48 Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching) Ultra compact unit (width 45 mm) Output: 3 N/Os, 1 N/C 1 or 2-channel configuration Line termination detection on the ON button Programmable: cross-fault detection in emergency stop-control loop Programmable: automatically comes on when operational voltage is applied or activation must happen with the ON button LED indicators for channels 1 and 2 Option to monitor external protection Removable terminals Protection of humans and machines in accordance with: EC Directive for Machines 89/392/EEC, IEC 204 T 1, EN 60204 T 1, DIN VDE 0113 **Input:** | ---|--- Nom. voltage: | AC 230 V or DC 24 V Control voltage on S11: | 24 Vdc Min. voltage on S12, S21: | DC 21 V (activated device) **Output:** | Contact assignment: | 3 N/O, 1 N/C Response time with ON button: | 50 ms -25% +50% Response time, automatic: | 1 s -25% +50% On: | Downtime in case of interruption: | ...in secondary circuit (S12-S22): | 25 ms -25% +50% ...in network: | 50 ms -25% +50% Switching capability according to AC 15: | 5A / AC 250 V (N/O) | 2 A / AC 250 V (NC) **General data:** | Temperature range: | -15 °C → +55 °C Terminal positioning: | Compliant with DIN 46199-4 Device dimensions (W x H x D): | 45 x 74 x 121 mm ### Recognized BG # # # Standard EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Safety Relays9087
-
Category: Classification of electronic componentsDescription: PCB relay, single shot with forcibly guided contacts OA5669 (2 changeovers) With forcibly guided contacts Contact opening >0.5 mm throughout its service life, including malfunctions and @ 1.6 UN Air gap and creep distance, surface winding ≥8 mm High dielectric withstand voltage ≥4 kV Large voltage range 0.7 → 1.6 UN As per IEC 664/VDE 0110 (1 / 89): Rated voltage: 250 V, pollution degree: 3 Surge voltage category: III Fluxproof Designed as per DIN EN 50205 ZH 1 / 457 and VDE 0106, 0110, 0435, 0631, 0700, 0730, 0804 **Reel** | ---|--- Nom. voltage/ | Voltage range: | 24 Vdc / 19.2 → 38.4 Vdc Resistance @ 20°C: | 820 Ω Nominal consumption: | 0.7 W Contacts | Contact assignment: | 2 changeovers Contact material: | AgNi 10 + 0.2 μm Au Continuous current Ith max./min. | 1 x 8 A or 2 x 5 A / 0.1 A Max. switching capacity: AC/DC: | 2 x 1250 VA / 2 x 160 W Switching capability according to AC 11: | NC: 1 A | N/O: 3 A @ 230 Vac Max. Switching frequency: | 10 1/s Response/fallback time: | ≤10 / 12 ms General data | Mechanical lifespan: | ≥5 x 107 cycles Temperature range: | -40 °C → +60 °C Housing protection rating: | IP40, fluxproof ### Recognized T Ü V, UL, SA, SEV # # Standard EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Mandatory Guided Relays5065
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE BA 9041 3AC 50Hz 400V Phase Monitoring Relay, DPDT, DIN Rail, Screw, 230VAC6771
-
Category: Classification of electronic componentsDescription: BG5925/900 light barrier evaluation module For protecting people and machines The BG 5925 is also suitable for switching small loads thanks to gold-plated contacts Evaluation device for light barriers with self-test function Compliant with the EC Machines Directive 98/37/EC 1 or 2-channel configuration Activation via the ON button or automatic ON function when the operating voltage is met Line termination detection on the ON button Input | ---|--- Nominal voltage UN: | 24 Vdc Voltage range: | 0.9 → 1.1 UN Device protection: | Internal with PTC Overvoltage protection: | Internal via VDR Control current via S12, S22: | 40 mA at UN Minimum voltage on terminals S12, S22: | 21 Vdc when device is activated | Output | Contact assignment | 2 N/O Typical switch on time @ UN: | Manual start: 40 ms Automatic start: 250 ms Typical switch off time @ UN: | If supply voltage is interrupted: 50 ms If S12, S22 are interrupted: 15 ms Thermal current Ith: | max. 7A per contact Switching capability according to AC 15: | 3A @ 230 Vac EN 60 947-5-1 for NO Acceptable switching frequency: | max. 1200 cycles/h General data | Rated operating current type: | Continuous Temperature range: | -15 → +55 °C Housing/terminal protection class: | IP 40 / IP 20 Device dimensions (W x H x D): | 22.5 x 84 x 118 mm ### standard IEC 204-1, EN 60204-1, DIN VDE 0113-1, EN 954-1, DIN EN 954-1 (safety category 4) ### safety relay4706
-
Category: Classification of electronic componentsDescription: LG5924 - Emergency stop module Emergency stop relay compliant with the EC Directive on machines 98/37/EC 1-channel configuration LED status display Short circuit detection between terminal Y1 and earth Overall width of 22.5 mm ### Applications Protection of persons and machines Machine emergency stop switches ### Approval of CE # # # Standard IEC/EN 60204-1, VDE 0113 Part 1 (1998-11) # # # Safety Relays22621+$1619.333110+$1604.611925+$1597.251350+$1589.8907100+$1582.5301150+$1575.1695250+$1567.8089500+$1560.4483
-
Category: Classification of electronic componentsDescription: Phase monitor, BD9080 Multifunctional device for monitoring three-phase networks for undervoltage / overvoltage. Phase sequence asymmetry, mains failure (in accordance with IEC 255, VDE 0435 part 303). Recognition of - Undervoltages / overvoltages - Asymmetry - Phase failure - Phase sequence Impervious to harmonics up to a distortion factor of K 20 % Fallback delay adjustable from 0.1 → 5 s One LED indicator for each of the following: auxiliary voltage A1 / A2; overvoltage UMAX; undervoltage UMIN; asymmetry / phase sequence / mains failure; contact position One device for networks with and without a neutral conductor Rest current principle 2 changeovers Overall width 45 mm ### Phase sequence/fault relay monitoring three-phase power supply orange shell manufacturing in accordance with DIN 43 880 DIN rail installation85961+$3810.038110+$3775.401425+$3758.083050+$3740.7647100+$3723.4463150+$3706.1280250+$3688.8096500+$3671.4913
-
Category: Classification of electronic componentsDescription: Emergency stop module, BO5988.47 / 124 Machine emergency stop switches Monitoring sliding grill guards SK 4 (with equivalent switching) Output: 3 NO, 1 delayed NO, 1 NC for 250 Vac Two rated voltages in one device 1 or 2-channel configuration Line fault detection in the emergency stop control circuit Optional: cross-fault detection in the emergency stop control circuit Optional: automatic ON function when operational voltage is met or system is activated via ON button LED displays for channel 1 and channel 2 and operational mode Control loop X1 - X2 for monitoring external contactors Integrated short-circuit and overvoltage protection Removable terminals Protection of personnel and machines in accordance with: EC Machinery Directive 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113 ### Recognized BG, SUVA, UL, CSA # # # Standard EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1 # # # Safety Relays2336
-
Category: Classification of electronic componentsDescription: IL9077 - Over and under voltage relay Detection of over voltage, under voltage and phase failure Network error diagnosis through more LEDs Response values for over and under voltage separately adjustable Adjustment ranges 0.9 → 1.3 UN and / or 0.7 → 1.1 UN Adjustable time delays from 0.1 → 20 s Nom. voltage: 3 AC 230 / 400 V, 50 / 60 Hz Voltage range: 0.7 → 1.3 UN Overload capability: 1.35 UN continuous Rest current principle Without auxiliary voltage Any phase sequence Nominal operating mode: Continuous operation Can also be used as single phase 2 changers Protection class (housing / terminals): IP40/IP20 Overall width 35 mm To IEC 255, VDE 0435 section 303 Manuf. ref.: IL9077.12 3/N AC 400/230 0.1 → 20 s ### Phase sequence/fault relay monitoring three-phase power supply orange shell manufacturing in accordance with DIN 43 880 DIN rail installation3818
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE BH 9097.38/001 3AC 400V 50/60Hz 40A Phase Monitoring Relay, DPDT, DIN Rail, Screw3326
-
Category: Classification of electronic componentsDescription: Voltage relay, three-phase, BA9043, BA9043/001 Voltage monitoring for 3 phase systems 3 phase mains, 50 → 400 Hz Arithmetic average measurement Adjustable response and fall-back values For mains with or without a neutral conductor Closed circuit current principle; output relay not activated in the event of a fault LED status displays Impervious to harmonics Overall width 45 mm **Input** Overload capability: 1.2 UN continuous Response value RAN: 0.85 → 1.05 UN adjustable Fall-back value: 0.75 → 0.95 UAN adjustable **Output** Contact assignment: 2 changeovers Contact type: Spring contact Thermal current: 6 A Switching capacity: 3 A (as per AC 11, 230 V), 2 A (as per DC 11, 24 V) ### Phase sequence/fault relay monitoring three-phase power supply orange shell manufacturing in accordance with DIN 43 880 DIN rail installation8587
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE BA 9043/001 3AC 50/60HZ 400V Voltage monitoring relay, BA 9043 series, DPDT, 3A, DIN rail installation, 230 VAC, screw61471+$861.599510+$831.367950+$827.5890100+$823.8100150+$817.7637250+$812.4732500+$807.18271000+$801.1363
-
Category: Classification of electronic componentsDescription: MK 9040N - Asymmetry relay Detects voltage asymmetry, phase loss, reverse voltage and phase sequence Impervious to symmetrical harmonics up to distortion factor of K 20 % 2 LED displays for voltage supply and contact position Output contact 2 changeovers Overall width: 22.5 mm For monitoring three-phase networks, e.g. lifts, escalators, hoisting systems, etc. **Input** | ---|--- Nominal voltage UN: | 400 Vac, 3-phase Voltage range: | 0.8 → 1.1 UN Nominal frequency: | 50 / 60 Hz Nominal consumption: | approx. 4.8 VA **Output** | Contact assignment: | 2 changeovers Response/fallback time: | ≤1 s / ≤250 ms Thermal current: | 6A Switching capacity (as per AC-15): | \- NO contact | 3 A @ 230 Vac \- NC contact | 1 A @ 230 Vac **General data:** | Rated operating current type: | Continuous Mounting: | DIN Track Temperature range: | -20 °C → +60 °C Device dimensions (W x H x D): | 22.5 x 90 x 100 mm Weight: | 145 g ### Phase sequence/fault relay monitoring three-phase power supply orange shell manufacturing in accordance with DIN 43 880 DIN rail installation4069
-
Category: Classification of electronic componentsDescription: DOLD & SOEHNE MK 9151.11 2 - 450K - OHM DC 24V Liquid level detection relay52891+$580.345510+$559.982550+$557.4371100+$554.8918150+$550.8192250+$547.2556500+$543.69211000+$539.6195