产品列表
Product Information
Description
Inventory
Gradient pricing
  • Brand: DTS
    Encapsulation:
    Description: 1、2、21 The 22 Ex-e DTS EVS-EMA series is an emergency lighting hazardous area Ex e fluorescent fixture designed for use in zones 1, 2, 21, and 22, allowing the same emergency lighting equipment to be used throughout the entire hazardous area site while meeting evacuation standards. The EVS-EMA ATEX lighting fixture perfectly combines high quality with a wide range of functions. The main body is made of GRP and has a high impact strength polycarbonate diffuser that can resist harsh and corrosive environments. The electronic ballast is equipped with a 220-240V 50/60Hz battery that can be used continuously for 3 hours. The emergency fluorescent lamp is equipped with an automatic 5-wire circuit transparent LED for easy visual inspection. The battery automatically shuts down when opened for safety maintenance. All components are installed on a hinged and detachable gear tray for easy access and installation and maintenance. No lamp approval is provided EN60079-.0,60079-1,60079-5,60079-7,61241-1 LCIE 11 ATEX 3065X IEC Ex LCI 11,0053X Ex II 2 G Ex de IIC T4 Gb, Used for Ex de IIC T5 Gb from ≤ -40 ° C to ≤+60 ° C, Ex II 2D from ≤ -40 ° C to ≤+35 ° C, Ex tb IIIC T85 ° C Db IP6x IEC 60529 (2001) IP66 comes with a nylon M20 cable fixing head cable (6-12mm), two M20 nylon plugs, and two galvanized steel brackets for ceiling installation (V015). There are two basic types of emergency lighting accessories - maintenance type and non maintenance type. The advantage of these maintenance type luminaires is that they can switch between maintenance type (the light stays on) and non maintenance type (the light will not turn off until the power is disconnected) functions, making them suitable for applications such as emergency exit signs in corridors, workshops, and permanent lighting. The maintenance type lighting fixture also has a tool that can switch up to ten devices together. Non maintenance type, these lighting fixtures only light up when there is a power failure. Suitable for emergency exits, power distribution rooms, and stor
    5821
  • Brand: DTS
    Encapsulation:
    Description: 2 The 22 Ex nR DTS EVN series hazardous area Ex nR fluorescent lamps are designed for use in Zone 2 and 22, making them particularly suitable for hazardous areas affected by dust. EVN lighting fixtures perfectly combine high quality with a wide range of functions. Electronic ballast, 110-260V 50/60Hz body made of GRP, with high impact intensity fluorescent lamp 5-wire circuit polycarbonate diffuser that can resist harsh and corrosive environments. All components are installed on hinged and detachable gear trays for easy access, easy installation and maintenance. No lamp provided. EN60079-0, 60079-15, EN61241-1 Ex II 3 G Ex nR IIC T4 Gb approved, used for ≤ -40 ° C to ≤+60 ° C Ex nR IIC T6 Gb, used for ≤ -40 ° C to ≤+35 ° C Ex II 3 D Ex tc IIIC T100 ° C to T135 ° C Dc IP6x IEC 60529 (2001) IP66. Comes with a nylon M20 cable fixing head (6-12mm), two M20 nylon plugs, and two galvanized steel brackets for ceiling installation (V015) # # # Hazardous Area
    4055
  • Brand: DTS
    Encapsulation:
    Description: Ex de XF The DTS XF series floodlight accessories for hazardous areas Ex d have a sturdy design that is particularly suitable for many hazardous areas, whether it is oil, gas, or ships. The XF ATEX floodlights come with various fasteners, allowing them to be installed on many types of structures, including poles. This series of floodlights can be equipped with HP sodium lamps or metal halide lamps. Flood light, electrically plated steel flat mounting bracket compact, lightweight and sturdy ferromagnetic ballast 220 V 60 Hz manufactured as Ex d, but with Ex e integrated junction box, easy to install excellent metering characteristics, wide or narrow beam approved by international certification with accompanying lamp and cable fixing heads EN60079-0,60079-1,60079-7 LCIE 00 ATEX 6019X IECEx LCI 11-0062X Ex II 2 G、Ex de IIB T3 Gb, Used for Ex de IIB T2 Gb from ≤ -20 ° C to ≤+40 ° C, IEC 60529 (2001) IP66 with installed lights, one nickel plated brass M20 brake plug and one cable fixing head M20 for unarmored cables (10-16mm) in hazardous areas
    2288
  • Brand: DTS
    Encapsulation:
    Description: Ex de XF The DTS XF series floodlight accessories for hazardous areas Ex d have a sturdy design that is particularly suitable for many hazardous areas, whether it is oil, gas, or ships. The XF ATEX floodlights come with various fasteners, allowing them to be installed on many types of structures, including poles. This series of floodlights can be equipped with HP sodium lamps or metal halide lamps. Flood light, electrically plated steel flat mounting bracket compact, lightweight and sturdy ferromagnetic ballast 220 V 60 Hz manufactured as Ex d, but with Ex e integrated junction box, easy to install excellent metering characteristics, wide or narrow beam approved by international certification with accompanying lamp and cable fixing head # # # EN60079-0,60079-1,60079-7 LCIE 00 ATEX 6019X IECEx LCI 11-0062X Ex II 2 G、Ex de IIB T3 Gb, Used for Ex de IIB T2 Gb from ≤ -20 ° C to ≤+40 ° C, for IEC 60529 (2001) IP66 from ≤ -20 ° C to ≤+60 ° C, with accompanying lights installed, one nickel plated brass M20 brake plug and one cable fixing head M20, for unarmored cables (10-16mm), in hazardous areas
    8610
  • Brand: DTS
    Encapsulation:
    Description: 2 The 22 and Ex nR DTS EVN-EMA series are emergency lighting hazardous area Ex nR fluorescent lamps designed for use in Zone 2 and 22, making them particularly suitable for hazardous areas affected by dust and meeting evacuation standards. The EVN-EMA lighting fixture perfectly combines high quality with a wide range of functions. It is an emergency fluorescent lamp with an automatic test 5-wire circuit electronic ballast, 220-240V 50/60Hz body made of GRP, and high impact strength polycarbonate diffuser that can resist harsh and corrosive environments. It can automatically turn off the emergency mode when turned on for safe maintenance and can be used for 3 hours of continuous automatic testing. It is used for preventive maintenance. The transparent LED can easily visually detect battery failure. The lamp is approved by EN60079-0, 60079-15, EN61241-1 Ex II 3 G Ex nR IIC T4 Gb, used for ≤ -40 ° C to ≤+60 ° C Ex nR IIC T6 Gb, used for ≤ -40 ° C to ≤+35 ° C Ex tc IIIC T100 ° C to T135 ° C Dc IP6x IEC 60529 (2001) IP66 # # # comes with a nylon M20 cable fixing head (6-12mm) Two nylon plugs and two galvanized steel brackets for ceiling installation (V015) # # # Emergency light accessories come in two basic types of emergency lighting fixtures - maintenance type and non maintenance type. The advantage of these maintenance type luminaires is that they can switch between maintenance type (the light stays on) and non maintenance type (the light will not turn off until the power is disconnected) functions, making them suitable for applications such as emergency exit signs in corridors, workshops, and permanent lighting. The maintenance type lighting fixture also has a tool that can switch up to ten devices together. Non maintenance type, these lighting fixtures only light up when there is a power failure. Suitable for emergency exits, power distribution rooms, and storage areas.
    5663
  • Brand: DTS
    Encapsulation:
    Description: 1、2、21 The 22 Ex d DTS XEL hazardous area Ex d tubular fluorescent lamps are designed for use in zones 1, 2, 21, and 22, allowing the same emergency lighting equipment to be used throughout the entire hazardous area site, whether it is oil and gas or food and beverage. XEL ATEX lighting fixtures perfectly combine high quality with a wide range of functions. Miniature tubular fluorescent lamp - polycarbonate electronic ballast 220-240V 50/60Hz polished yellow offshore made of marine grade aluminum. All components are installed on a sliding gear tray for easy access, easy to install and maintain. When opened for safe maintenance, the main body automatically closes. Standard components are used internally to reduce maintenance costs. Lamp # # # Approved EN60079-.0,60079-31,60079-7,60079-1 INERIS II ATEX 0051X Ex II 2 G Ex d IIC T6 Gb Ex II 2 D Ex tb IIIC T80 ° C Db IP66 # # # Comes with a 3/4 "NPT brass cable fixing head, suitable for unarmored cables (12-16mm), a 3/4 NPT nickel plated brass brake plug, and two galvanized steel hinged brackets, suitable for ceiling installation (D023) # # # Hazardous area
    1911
  • Brand: DTS
    Encapsulation:
    Description: 1、2、21 The 22 Ex-e DTS EVS series hazardous area Ex e fluorescent lamps are designed for use in zones 1, 2, 21, and 22, allowing the same emergency lighting equipment to be used throughout the entire hazardous area site, whether it is oil and gas or food and beverage. EVS ATEX luminaires combine high quality with a wide range of features. Fluorescent lamp with easy to disconnect 5-wire or 3-wire circuit electronic ballast, 220-240V 50/60Hz body made of GRP, high impact strength polycarbonate diffuser, resistant to harsh environments, automatically shuts off when opened for safety maintenance. All components are installed on hinged and detachable gear trays for easy access, installation and maintenance. Lamp not provided. # # # Approved EN60079-0,60079-1,60079-5,60079-7,EN61241-1 LCIE 11 ATEX 3065X IEC Ex LCI 11,0053X Ex II 2 G Ex de IIC T4 Gb, Used for Ex de IIC T5 Gb from ≤ -40 ° C to ≤+60 ° C, Ex II 2 D Ex tb IIIC T85 ° C Db IP6x IEC 60529 (2001) IP66 # # # Comes with one nylon M20 cable fixing head (6-12mm), two M20 nylon plugs, and two galvanized steel brackets for ceiling installation (V015) # # # Hazardous area
    2864

©Copyright 2013-2025 ICGOODFIND (Shenzhen) Electronics Technology Co., Ltd.

Scroll